Ethernet OAM (Operations, Administration, and Maintenance)
Left running head:
Chapter name (automatic)
354
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Command Reference Guide
Alcatel-Lucent
FAULT-ALARM RESET-TIME
fault-alarm reset-time <250-1000>
DESCRIPTION
This is entered in the OAM Domain Association MEP Configuration Mode. This
command configures the fault alarm reset time (in milliseconds) on a MEP. During
this time interval, no fault alarms are generated.
PARAMETERS
DEFAULT VALUE
The default reset-time is 1000 milliseconds.
PLATFORMS SUPPORTED
OmniAccess 5740 USG
EXAMPLE
ALU(config-oam-domain-assoc-mep)# fault-alarm reset-time 400
RELEASE HISTORY
Release 3.0: command was introduced.
Parameter Description
250-1000 Specify the fault alarm reset time (in
milliseconds) on a MEP in the range
250-1000.