Ethernet OAM (Operations, Administration, and Maintenance)
Left running head:
Chapter name (automatic)
350
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Command Reference Guide
Alcatel-Lucent
ETH-CFM LOOPBACK
eth-cfm loopback <mac-address> mep <1-8191> domain <0-65535>
association <0-65535> [{datasize <1-255>|priority <0-7>|send-
count <1-5>}]
DESCRIPTION
This is entered in the OAM Configuration Mode. This command is used to initiate
a loopback test.
PARAMETERS
DEFAULT VALUE
None.
PLATFORMS SUPPORTED
OmniAccess 5740 USG
EXAMPLE
ALU(config-oam)# eth-cfm loopback 1111.1111.1111 mep 10 domain
1 association 10 datasize 100
RELEASE HISTORY
Release 3.0: command was introduced.
Parameter Description
mac-address MAC address given on the interface.
1-8191 An integer, unique over a given MA,
identifying a specific MEP.
0-65535 An unique integer identifying a specific
maintenance domain.
0-65535 An unique integer identifying a specific
maintenance association.
1-255 Specifies the size of data (in bytes) to be
sent as a part of loopback test.
priority Priority value set for CCM and LTMs on
a MEP.
1-5 Specifies the total number of loopback
frames to be sent as a part of loopback
test.