T1E1 Line Card
Left running head:
Chapter name (automatic)
240
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Command Reference Guide
Alcatel-Lucent
LINECODE
linecode {ami|hdb3}
DESCRIPTION
This command is entered in the Controller Configuration Mode to set a linecode
for the E1 interface. The E1 service provider determines which line-code type, ami
or hdb3, is required for your E1 circuit.
PARAMETERS
DEFAULT VALUE
HDB3 line code is the default for E1 lines.
EXAMPLE
ALU(config-controller E1)# linecode hdb3
LINE-TERMINATION
line-termination {75ohm|120ohm}
DESCRIPTION
This command is entered in the Controller Configuration Mode to configure a line
impedance of 75 or 120.
PARAMETERS
DEFAULT VALUE
The default line-termination value is 120 ohm.
EXAMPLE
ALU(config-controller E1)#line-termination 120
Parameter Description
ami Type of linecode.
hdb3 High-density bipolar 3 (HDB3) line-code
type. Valid for E1 controller only.
Parameter Description
75ohm|120ohm The line impedance value: 75 or 120
ohms.