frame-relay lmi-n391dte
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
281
Alcatel-Lucent
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Command Reference Guide
FRAME-RELAY LMI-N391DTE
frame-relay lmi-n391dte <1-255>
DESCRIPTION
This command is entered in the Interface Configuration Mode. This command is
used to set the full status polling interval on a DTE interface.
PARAMETERS
DEFAULT VALUE
The default polling interval is 6.
EXAMPLE
The following example sets the polling interval to 8.
ALU(config-if Serial0/0:0)#frame-relay lmi-n391dte 8
FRAME-RELAY LMI-N392DTE
frame-relay lmi-n392dte <1-10>
DESCRIPTION
This command is entered in the Interface Configuration Mode. It sets the DTE
error threshold.
PARAMETERS
DEFAULT VALUE
The default value is 3.
EXAMPLE
The following example sets the DTE error threshold to 6.
ALU(config-if Serial0/0:0)# frame-relay lmi-n392dte 6
Parameter Description
1-255 Interval in events when a full status
request is sent out.
Parameter Description
1-10 DTE error threshold value.