linecode
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
255
Alcatel-Lucent
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Command Reference Guide
LINECODE
linecode {ami|b8zs}
DESCRIPTION
This command is entered in the Controller Configuration Mode. Use this
command to configure the line-code type for a T1 line. The T1 service provider
determines which line-code type, ami or b8zs, is required for your T1 circuit.
PARAMETERS
DEFAULT VALUE
The default linecode value is b8zs.
EXAMPLE
The following example specifies AMI as the linecode type for a T1 line:
ALU(config-controller T1)# linecode ami
Parameter Description
ami Alternate Mark Inversion (AMI) line-code type.
Note: If ‘ami’ linecode is configured, configure
timeslot speed to 56Kbps to ensure 1st
density.
b8zs b8zs line-code type.