DescriptionResetTypeNameBit/Field
SS3 Trigger Select
This field selects the trigger source for Sample Sequencer 3.
The valid configurations for this field are:
EventValue
Processor (default)
The trigger is initiated by setting the SSn bit in the ADCPSSI
register.
0x0
Analog Comparator 0
This trigger is configured by the Analog Comparator Control
0 (ACCTL0) register (page 1665).
0x1
Analog Comparator 1
This trigger is configured by the Analog Comparator Control
1 (ACCTL1) register (page 1665).
0x2
Analog Comparator 2
This trigger is configured by the Analog Comparator Control
2 (ACCTL2) register (page 1665).
0x3
External (GPIO Pins)
This trigger is connected to the GPIO interrupt for the
corresponding GPIO (see “ADC Trigger Source” on page 750).
0x4
Timer
In addition, the trigger must be enabled with the TnOTE bit
in the GPTMCTL register (page 986).
0x5
PWM generator 0
The PWM generator 0 trigger can be configured with the
PWM0 Interrupt and Trigger Enable (PWM0INTEN) register
(page 1713).
0x6
PWM generator 1
The PWM generator 1 trigger can be configured with the
PWM1INTEN register (page 1713).
0x7
PWM generator 2
The PWM generator 2 trigger can be configured with the
PWM2INTEN register (page 1713).
0x8
PWM generator 3
The PWM generator 3 trigger can be configured with the
PWM3INTEN register (page 1713).
0x9
reserved0xA-0xD
Never Trigger (No triggers are allowed to the ADC digital
interface)
0xE
Always (continuously sample)0xF
0x0RWEM315:12
June 18, 20141092
Texas Instruments-Production Data
Analog-to-Digital Converter (ADC)