EasyManuals Logo
Home>Texas Instruments>Microcontrollers>TM4C1294NCPDT

Texas Instruments TM4C1294NCPDT User Manual

Texas Instruments TM4C1294NCPDT
1890 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #238 background imageLoading...
Page #238 background image
If the main oscillator provides the clock reference to the PLL, the translation provided by hardware
and used to program the PLL is available for software in the PLL Frequency n (PLLFREQn) registers
(see page 292). The internal translation provides a translation within ± 1% of the targeted PLL VCO
frequency. Table 5-7 on page 238 shows the actual PLL frequency and error for a given crystal
choice.
Table 5-7 on page 238 provides examples of the programming expected for the PLLFREQ0 and
PLLFREQ1 registers. The first column specifies the input crystal frequency and the last column
displays the PLL frequency given the values of MINT and N, when Q=0.
Table 5-7. Actual PLL Frequency
a
PLL Frequency
(MHz)
Reference
Frequency
(MHz)
b
NMINT (Hexadecimal
Value)
MINT (Decimal
Value)
Crystal
Frequency
(MHz)
32050x00x40645
32020x20x351606
32080x00x28408
320100x00x203210
32040x20x508012
320160x00x142016
32020x80xA016018
320200x00x101620
32080x20x284024
32050x40x406425
48050x00x60965
48060x00x50806
48080x00x3C608
480100x00x304810
480120x00x284012
480160x00x1E3016
48060x20x508018
480200x00x182420
480240x00x142024
48050x40x609625
a. For all examples listed, Q=0
b. For a given crystal frequency, N should be chosen such that the reference frequency is within 4 to 30 MHz.
PLL Operation
If a PLL configuration is changed, the PLL output frequency is unstable until it reconverges (relocks)
to the new setting. The time between the configuration change and relock is T
READY
(see Table
27-16 on page 1835). During the relock time, the affected PLL is not usable as a clock reference.
Software can poll the LOCK bit in the PLL Status (PLLSTAT) register to determine when the PLL
has locked.
Modification of the PLL VCO frequency may not be performed while the PLL serves as a clock
source to the system. All changes to the PLL must be performed using a different clock source until
the PLL has locked frequency. Thus, changing the PLL VCO frequency must be done as a sequence
from PLL to PIOSC/MOSC and then PIOSC/MOSC to new PLL.
June 18, 2014238
Texas Instruments-Production Data
System Control

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments TM4C1294NCPDT and is the answer not in the manual?

Texas Instruments TM4C1294NCPDT Specifications

General IconGeneral
BrandTexas Instruments
ModelTM4C1294NCPDT
CategoryMicrocontrollers
LanguageEnglish

Related product manuals