DescriptionResetTypeNameBit/Field
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0ROreserved31:8
General-Purpose Timer 7 Power Control
The Pn bit encodings are not applicable if the corresponding bit in the
RCGCTIMER, SCGCTIMER or DCGCTIMER register is clear.
DescriptionValue
Timer 7 module is not powered and does not receive a clock.
In this case, the module's state is not retained.
This configuration provides the lowest power consumption state.
0
Timer 7 module is powered, but does not receive a clock. In this
case, the module is inactive.
1
1RWP77
General-Purpose Timer 6 Power Control
The Pn bit encodings are not applicable if the corresponding bit in the
RCGCTIMER, SCGCTIMER or DCGCTIMER register is clear.
DescriptionValue
Timer 6 module is not powered and does not receive a clock.
In this case, the module's state is not retained.
This configuration provides the lowest power consumption state.
0
Timer 6 module is powered, but does not receive a clock. In this
case, the module is inactive.
1
1RWP66
General-Purpose Timer 5 Power Control
The Pn bit encodings are not applicable if the corresponding bit in the
RCGCTIMER, SCGCTIMER or DCGCTIMER register is clear.
DescriptionValue
Timer 5 module is not powered and does not receive a clock.
In this case, the module's state is not retained.
This configuration provides the lowest power consumption state.
0
Timer 5 module is powered, but does not receive a clock. In this
case, the module is inactive.
1
1RWP55
General-Purpose Timer 4 Power Control
The Pn bit encodings are not applicable if the corresponding bit in the
RCGCTIMER, SCGCTIMER or DCGCTIMER register is clear.
DescriptionValue
Timer 4 module is not powered and does not receive a clock.
In this case, the module's state is not retained.
This configuration provides the lowest power consumption state.
0
Timer 4 module is powered, but does not receive a clock. In this
case, the module is inactive.
1
1RWP44