DescriptionResetTypeNameBit/Field
CRC Module Power Control
The Pn bit encodings are not applicable if the corresponding bit in the
RCGCCCM, SCGCCCM or DCGCCCM register is clear.
DescriptionValue
The CRC module is not powered and does not receive a clock.
In this case, the module's state is not retained.
This configuration provides the lowest power consumption state.
0
The CRC module is powered, but does not receive a clock. In
this case, the module is inactive.
1
1RWP00
493June 18, 2014