DescriptionResetTypeNameBit/Field
Generator 1 PWM Module Trigger Select
This field selects in which PWM module the Generator 1 trigger is
located.
DescriptionValue
Use Generator 1 (and its trigger) in PWM module 00x0
reserved0x1-0x3
0x0RWPS113:12
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0ROreserved11:6
Generator 0 PWM Module Trigger Select
This field selects in which PWM module the Generator 0 trigger is
located.
DescriptionValue
Use Generator 0 (and its trigger) in PWM module 00x0
reserved0x1-0x3
0x0RWPS05:4
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0ROreserved3:0
June 18, 20141098
Texas Instruments-Production Data
Analog-to-Digital Converter (ADC)