DescriptionResetTypeNameBit/Field
4th Sample Input Select
The MUX3 field is used during the fourth sample of a sequence executed
with the sample sequencer. It specifies which of the analog inputs is
sampled for the analog-to-digital conversion.
0x0RWMUX315:12
3rd Sample Input Select
The MUX2 field is used during the third sample of a sequence executed
with the sample sequencer. It specifies which of the analog inputs is
sampled for the analog-to-digital conversion.
0x0RWMUX211:8
2nd Sample Input Select
The MUX1 field is used during the second sample of a sequence
executed with the sample sequencer. It specifies which of the analog
inputs is sampled for the analog-to-digital conversion.
0x0RWMUX17:4
1st Sample Input Select
The MUX0 field is used during the first sample of a sequence executed
with the sample sequencer. It specifies which of the analog inputs is
sampled for the analog-to-digital conversion.
0x0RWMUX03:0
June 18, 20141110
Texas Instruments-Production Data
Analog-to-Digital Converter (ADC)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments TM4C1294NCPDT and is the answer not in the manual?

Texas Instruments TM4C1294NCPDT Specifications

General IconGeneral
BrandTexas Instruments
ModelTM4C1294NCPDT
CategoryMicrocontrollers
LanguageEnglish

Related product manuals