DescriptionResetTypeNameBit/Field
6th Sample Input Select (Upper Bit)
The EMUX5 field is used during the sixth sample of a sequence executed
with the sample sequencer. This bit has the same description as EMUX7.
0x0RWEMUX520
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0ROreserved19:17
5th Sample Input Select (Upper Bit)
The EMUX4 field is used during the fifth sample of a sequence executed
with the sample sequencer. This bit has the same description as EMUX7.
0x0RWEMUX416
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0ROreserved15:13
4th Sample Input Select (Upper Bit)
The EMUX3 field is used during the fourth sample of a sequence executed
with the sample sequencer. This bit has the same description as EMUX7.
0x0RWEMUX312
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0ROreserved11:9
3rd Sample Input Select (Upper Bit)
The EMUX2 field is used during the third sample of a sequence executed
with the sample sequencer. This bit has the same description as EMUX7.
0x0RWEMUX28
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0ROreserved7:5
2th Sample Input Select (Upper Bit)
The EMUX1 field is used during the second sample of a sequence
executed with the sample sequencer. This bit has the same description
as EMUX7.
0x0RWEMUX14
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0ROreserved3:1
1st Sample Input Select (Upper Bit)
The EMUX0 field is used during the first sample of a sequence executed
with the sample sequencer. This bit has the same description as EMUX7.
0x0RWEMUX00
June 18, 20141126
Texas Instruments-Production Data