DescriptionResetTypeNameBit/Field
6th Sample and Hold Period Select
The TSH5 field is used during the sixth sample of a sequence executed
with the sample sequencer.
0x0RWTSH523:20
5th Sample and Hold Period Select
The TSH4 field is used during the fifth sample of a sequence executed
with the sample sequencer.
0x0RWTSH419:16
4th Sample and Hold Period Select
The TSH3 field is used during the fourth sample of a sequence executed
with the sample sequencer.
0x0RWTSH315:12
3rd Sample and Hold Period Select
The TSH2 field is used during the third sample of a sequence executed
with the sample sequencer.
0x0RWTSH211:8
2nd Sample and Hold Period Select
The TSH1 field is used during the second sample of a sequence
executed with the sample sequencer.
0x0RWTSH17:4
1st Sample and Hold Period Select
The TSH0 field is used during the first sample of a sequence executed
with the sample sequencer.
0x0RWTSH03:0
June 18, 20141128
Texas Instruments-Production Data
Analog-to-Digital Converter (ADC)