EasyManuals Logo
Home>Texas Instruments>Microcontrollers>TM4C1294NCPDT

Texas Instruments TM4C1294NCPDT User Manual

Texas Instruments TM4C1294NCPDT
1890 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1138 background imageLoading...
Page #1138 background image
DescriptionResetTypeNameBit/Field
3rd Sample Input Select (Upper Bit)
The EMUX2 field is used during the third sample of a sequence executed
with the sample sequencer. This bit has the same description as EMUX3.
0x0RWEMUX28
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0ROreserved7:5
2th Sample Input Select (Upper Bit)
The EMUX1 field is used during the second sample of a sequence
executed with the sample sequencer. This bit has the same description
as EMUX3.
0x0RWEMUX14
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0ROreserved3:1
1st Sample Input Select (Upper Bit)
The EMUX0 field is used during the first sample of a sequence executed
with the sample sequencer. This bit has the same description as EMUX3.
0x0RWEMUX00
June 18, 20141138
Texas Instruments-Production Data
Analog-to-Digital Converter (ADC)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments TM4C1294NCPDT and is the answer not in the manual?

Texas Instruments TM4C1294NCPDT Specifications

General IconGeneral
BrandTexas Instruments
ModelTM4C1294NCPDT
CategoryMicrocontrollers
LanguageEnglish

Related product manuals