DescriptionResetTypeNameBit/Field
Debug Mode
DescriptionValue
The counter stops running when it next reaches 0 and continues
running again when no longer in Debug mode.
0
The counter always runs when in Debug mode.1
0RWDEBUG2
Counter Mode
DescriptionValue
The counter counts down from the load value to 0 and then
wraps back to the load value (Count-Down mode).
0
The counter counts up from 0 to the load value, back down to
0, and then repeats (Count-Up/Down mode).
1
0RWMODE1
PWM Block Enable
Note: Disabling the PWM by clearing the ENABLE bit does not clear
the COUNT field of the PWMnCOUNT register. Before
re-enabling the PWM (ENABLE = 0x1), the COUNT field should
be cleared by resetting the PWM registers through the
SRPWM register in the System Control Module.
DescriptionValue
The entire PWM generation block is disabled and not clocked.0
The PWM generation block is enabled and produces PWM
signals.
1
0RWENABLE0
June 18, 20141712
Texas Instruments-Production Data
Pulse Width Modulator (PWM)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments TM4C1294NCPDT and is the answer not in the manual?

Texas Instruments TM4C1294NCPDT Specifications

General IconGeneral
BrandTexas Instruments
ModelTM4C1294NCPDT
CategoryMicrocontrollers
LanguageEnglish

Related product manuals