DescriptionResetTypeNameBit/Field
Action for Counter=LOAD
This field specifies the action to be taken when the counter matches the
value in the PWMnLOAD register.
DescriptionValue
Do nothing.0x0
Invert pwmA.0x1
Drive pwmA Low.0x2
Drive pwmA High.0x3
0x0RWACTLOAD3:2
Action for Counter=0
This field specifies the action to be taken when the counter is zero.
DescriptionValue
Do nothing.0x0
Invert pwmA.0x1
Drive pwmA Low.0x2
Drive pwmA High.0x3
0x0RWACTZERO1:0
June 18, 20141726
Texas Instruments-Production Data
Pulse Width Modulator (PWM)