DescriptionResetTypeNameBit/Field
Pump Voltage Interrupt Mask
DescriptionValue
The VOLTRIS interrupt is suppressed and not sent to the
interrupt controller.
0
An interrupt is sent to the interrupt controller when the VOLTRIS
bit is set.
1
0RWVOLTMASK9
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0ROreserved8:3
EEPROM Interrupt Mask
DescriptionValue
The ERIS interrupt is suppressed and not sent to the interrupt
controller.
0
An interrupt is sent to the interrupt controller when the ERIS bit
is set.
1
0RWEMASK2
Programming Interrupt Mask
This bit controls the reporting of the programming raw interrupt status
to the interrupt controller.
DescriptionValue
The PRIS interrupt is suppressed and not sent to the interrupt
controller.
0
An interrupt is sent to the interrupt controller when the PRIS bit
is set.
1
0RWPMASK1
Access Interrupt Mask
This bit controls the reporting of the access raw interrupt status to the
interrupt controller.
DescriptionValue
The ARIS interrupt is suppressed and not sent to the interrupt
controller.
0
An interrupt is sent to the interrupt controller when the ARIS bit
is set.
1
0RWAMASK0
June 18, 2014634
Texas Instruments-Production Data
Internal Memory