DescriptionResetTypeNameBit/Field
MnPWM6 Enable Update Mode
DescriptionValue
Immediate
Writes to the PWM6EN bit in the PWMENABLE register are used
by the PWM generator immediately.
0x0
Reserved0x1
Locally Synchronized
Writes to the PWM6EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0.
0x2
Globally Synchronized
Writes to the PWM6EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0 after a
synchronous update has been requested through the PWM
Master Control (PWMCTL) register.
0x3
0RWENUPD613:12
MnPWM5 Enable Update Mode
DescriptionValue
Immediate
Writes to the PWM5EN bit in the PWMENABLE register are used
by the PWM generator immediately.
0x0
Reserved0x1
Locally Synchronized
Writes to the PWM5EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0.
0x2
Globally Synchronized
Writes to the PWM5EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0 after a
synchronous update has been requested through the PWM
Master Control (PWMCTL) register.
0x3
0RWENUPD511:10
MnPWM4 Enable Update Mode
DescriptionValue
Immediate
Writes to the PWM4EN bit in the PWMENABLE register are used
by the PWM generator immediately.
0x0
Reserved0x1
Locally Synchronized
Writes to the PWM4EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0.
0x2
Globally Synchronized
Writes to the PWM4EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0 after a
synchronous update has been requested through the PWM
Master Control (PWMCTL) register.
0x3
0RWENUPD49:8
1705June 18, 2014
Texas Instruments-Production Data
Tiva
™
TM4C1294NCPDT Microcontroller