DescriptionResetTypeNameBit/Field
MnPWM3 Enable Update Mode
DescriptionValue
Immediate
Writes to the PWM3EN bit in the PWMENABLE register are used
by the PWM generator immediately.
0x0
Reserved0x1
Locally Synchronized
Writes to the PWM3EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0.
0x2
Globally Synchronized
Writes to the PWM3EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0 after a
synchronous update has been requested through the PWM
Master Control (PWMCTL) register.
0x3
0RWENUPD37:6
MnPWM2 Enable Update Mode
DescriptionValue
Immediate
Writes to the PWM2EN bit in the PWMENABLE register are used
by the PWM generator immediately.
0x0
Reserved0x1
Locally Synchronized
Writes to the PWM2EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0.
0x2
Globally Synchronized
Writes to the PWM2EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0 after a
synchronous update has been requested through the PWM
Master Control (PWMCTL) register.
0x3
0RWENUPD25:4
MnPWM1 Enable Update Mode
DescriptionValue
Immediate
Writes to the PWM1EN bit in the PWMENABLE register are used
by the PWM generator immediately.
0x0
Reserved0x1
Locally Synchronized
Writes to the PWM1EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0.
0x2
Globally Synchronized
Writes to the PWM1EN bit in the PWMENABLE register are used
by the PWM generator the next time the counter is 0 after a
synchronous update has been requested through the PWM
Master Control (PWMCTL) register.
0x3
0RWENUPD13:2
June 18, 20141706
Texas Instruments-Production Data
Pulse Width Modulator (PWM)