Macro
Table 1-43. (continued)
Error Status Registers Interpretation
Error Code 2 (32-bit) If RX DDC Configuration is in error
Bit[11:0]: RESERVED
Bit[12]: ‘1’ Interface rate for 1RX does not support dual band configuration
Bit[13]: ‘1’ Interface rate for 2RX does not support dual band configuration
Bit[14]: ‘1’ Interface rate for 3RX does not support dual band configuration
Bit[15]: ‘1’ Interface rate for 4RX does not support dual band configuration
Bit[19:16] RESERVED
Bit[20]: ‘1’ ADC Rate, Interface Rate Combination for 1RX is not supported
Bit[21]: ‘1’ ADC Rate, Interface Rate Combination for 2RX is not supported
Bit[22]: ‘1’ ADC Rate, Interface Rate Combination for 3RX is not supported
Bit[23]: ‘1’ ADC Rate, Interface Rate Combination for 4RX is not supported
Bit[31:24]: RESERVED
If FB DDC Configuration is in error
Bit[1:0]: RESERVED
Bit[2]: ‘1’ ADC Rate, Interface Rate Combination for 1FB is not supported
Bit[3]: ‘1’ ADC Rate, Interface Rate Combination for 2FB is not supported
If TX DUC Configuration is in error Bit[3:0]: RESERVED
Bit[4]: ‘1’ Configuration requested for 1TX is not supported
Bit[5]: ‘1’ Configuration requested for 2TX is not supported
Bit[6]: ‘1’ Configuration requested for 3TX is not supported
Bit[7]: ‘1’ Configuration requested for 4TX is not supported
Bit[31:8] Reserved
1.2.2.2 Apply DSA Gain-Phase Compensation Macro
This macro configures the RX/TX DSA Gain-Phase calibration parameters by parsing through the
calibration packet which should be loaded in MACRO_MEMORY prior to calling this macro.
Table 1-44.
Macro Apply DSA-GP factory calibration data
Opcode 0x11
Operand Offset Length Value Functionality Results
1 0x00 1 Calibration Appl.
Choice
0 Treat the
packet loaded in
memory as TX-DSA
Gain Phase
Calibration Packet
and program the
calibration
parameters.
1 Treat the
packet loaded in
memory as RX-DSA
Gain Phase
Calibration Packet
and program the
calibration
parameters
Memory DSA Calibration Packet
1.2.2.2.1 Error Reporting
Table 1-45.
Error Status Registers Interpretation
Error Code 1 (16-bit) 0 NO_ERROR
1 RESERVED
2 PKT_CHECKSUM_FAILED: Checksum check on loaded
packet failed
>2 RESERVED

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments AFE79 Series and is the answer not in the manual?

Texas Instruments AFE79 Series Specifications

General IconGeneral
BrandTexas Instruments
ModelAFE79 Series
CategoryControl Unit
LanguageEnglish

Related product manuals