EasyManua.ls Logo

Texas Instruments AFE79 Series - 2.4.201 Register 102 h (offset = 102 h) [reset = 0 h]; 2.4.202 Register 103 h (offset = 103 h) [reset = 0 h]

Texas Instruments AFE79 Series
1268 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DAC JESD Register Map
www.ti.com
336
SBAU337May 2020
Submit Documentation Feedback
Copyright © 2020, Texas Instruments Incorporated
Serial Interface Register Maps
Table 2-433. Register 101 Field Descriptions
Bit Field Type Reset Description
7-0
ALARMS_CLEAR[
15:8]
R/W 0h
Clear 'alarms' register to the alarm pin; Alarms won't be
generated if '1' so it must be programmed to '0' for alarms to
continue.
[8] = SRX1/5 LOS indicator
[9] = SRX2/6 LOS indicator
[10]= SRX3/7 LOS indicator
[11]= SRX4/8 LOS indicator
[12]= SRX1/5 Serdes-FIFO error
[13]= SRX2/6 Serdes-FIFO error
[14]= SRX3/7 Serdes-FIFO error
[15]= SRX4/8 Serdes-FIFO error
Note: Refer to the TI application note for details on error
interpretation.
2.4.201 Register 102h (offset = 102h) [reset = 0h]
Figure 2-430. Register 102h
7 6 5 4 3 2 1 0
ALARMS_CLEAR[23:16]
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-434. Register 102 Field Descriptions
Bit Field Type Reset Description
7-0
ALARMS_CLEAR[
23:16]
R/W 0h
Clear 'alarms' register to the alarm pin; Alarms won't be
generated if '1' so it must be programmed to '0' for alarms to
continue.
[23:16] = TIED to 0
Note: Refer to the TI application note for details on error
interpretation.
2.4.202 Register 103h (offset = 103h) [reset = 0h]
Figure 2-431. Register 103h
7 6 5 4 3 2 1 0
ALARMS_CLEAR[31:24]
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset