2.12.106 Register 512h (offset = 512h) [reset = 0h]
Figure 2-1309. Register 512h
7 6 5 4 3 2 1 0
TX_DUAL_BAND_COMBINER_PAP_MOVING_AVERAGE_ERROR_WINDOW_COUNTER[7:0]
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1321. Register 512 Field Descriptions
Bit Field Type Reset Description
7-0
TX_DUAL_BAND_
COMBINER_PAP_
MOVING_AVERAG
E_ERROR_WIND
OW_COUNTER[7:
0]
R/W 0h
In the Dual band combiner PA Protection moving average
module, when the moving average exceeds a thershold error
hit is generated. The PA protection can be triggered when the
number of such hits in a programmable window exceeds the
count threshold. The error accumulation window counter is
programmable with value in the range 0 to 2^12-1. The actual
window length is programmed_value + 1. The error count
threshold is programmed in the register
tx_dual_band_combiner_pap_moving_average_error_threshol
d.
2.12.107 Register 513h (offset = 513h) [reset = 0h]
Figure 2-1310. Register 513h
7 6 5 4 3 2 1 0
TX_DUAL_BAND_COMBINER_PAP_MOVING_AVERAGE_ERROR
_WINDOW_COUNTER[11:8]
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1322. Register 513 Field Descriptions
Bit Field Type Reset Description
3-0
TX_DUAL_BAND_
COMBINER_PAP_
MOVING_AVERAG
E_ERROR_WIND
OW_COUNTER[11
:8]
R/W 0h
In the Dual band combiner PA Protection moving average
module, when the moving average exceeds a thershold error
hit is generated. The PA protection can be triggered when the
number of such hits in a programmable window exceeds the
count threshold. The error accumulation window counter is
programmable with value in the range 0 to 2^12-1. The actual
window length is programmed_value + 1. The error count
threshold is programmed in the register
tx_dual_band_combiner_pap_moving_average_error_threshol
d.
2.12.108 Register 514h (offset = 514h) [reset = 0h]
Figure 2-1311. Register 514h
7 6 5 4 3 2 1 0
TX_DUAL_BAND_COMBINER_PAP_MOVING_AVERAGE_ERROR_THRESHOLD[7:0]
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset