2.6.65 Register 4098h (offset = 4098h) [reset = 0h]
Figure 2-779. Register 4098h
7 6 5 4 3 2 1 0
READ_PRBS_ERR_HIGH[7:0]
R-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-785. Register 4098 Field Descriptions
Bit Field Type Reset Description
7-0
READ_PRBS_ERR
_HIGH[7:0]
R 0h
Read only value of the upper word of the RX PRBS 32-bit
error count.
2.6.66 Register 4099h (offset = 4099h) [reset = 0h]
Figure 2-780. Register 4099h
7 6 5 4 3 2 1 0
READ_PRBS_ERR_HIGH[15:8]
R-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-786. Register 4099 Field Descriptions
Bit Field Type Reset Description
7-0
READ_PRBS_ERR
_HIGH[15:8]
R 0h
Read only value of the upper word of the RX PRBS 32-bit
error count.
2.6.67 Register 409Ah (offset = 409Ah) [reset = 0h]
Figure 2-781. Register 409Ah
7 6 5 4 3 2 1 0
READ_PRBS_ERR_LOW[7:0]
R-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-787. Register 409A Field Descriptions
Bit Field Type Reset Description
7-0
READ_PRBS_ERR
_LOW[7:0]
R 0h
Read only value of the lower word of the RX PRBS 32-bit
error count.
2.6.68 Register 409Bh (offset = 409Bh) [reset = 0h]
Figure 2-782. Register 409Bh
7 6 5 4 3 2 1 0
READ_PRBS_ERR_LOW[15:8]
R-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset

Table of Contents