EasyManua.ls Logo

Texas Instruments AFE79 Series - 2.12.114 Register 51 Ah (offset = 51 Ah) [reset = 0 h]; 2.12.115 Register 51 Ch (offset = 51 Ch) [reset = 0 h]

Texas Instruments AFE79 Series
1268 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TX Top Register Map
www.ti.com
668
SBAU337May 2020
Submit Documentation Feedback
Copyright © 2020, Texas Instruments Incorporated
Serial Interface Register Maps
Table 2-1328. Register 519 Field Descriptions
Bit Field Type Reset Description
0-0
TX_DUAL_BAND_
COMBINER_PAP_
MODE_HPF_NO_
AVG
R/W 0h
The high pass filter output can be averaged in a
programmable window of 2 to 16 samples. The averaged
output is compared against a threshold to determine the error
hit. However, the averaging can be bypassed and the
instantaneous filter output is compared against the threshold.
If this register bit is set to 1 the averaging is disabled and
instantaneous filter output is compared against the threshold.
0 : Average enable
1 : Average disable.
2.12.114 Register 51Ah (offset = 51Ah) [reset = 0h]
Figure 2-1317. Register 51Ah
7 6 5 4 3 2 1 0
TX_DUAL_BAND_COMBINER_
PAP_HPF_AVERAGING_SAMP
LE_COUNT
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1329. Register 51A Field Descriptions
Bit Field Type Reset Description
1-0
TX_DUAL_BAND_
COMBINER_PAP_
HPF_AVERAGING
_SAMPLE_COUNT
R/W 0h
The high pass filter output can be averaged in a
programmable window of 2 to 16 samples. The averaged
output is compared against a threshold to determine the error
hit.
0:2
1:4
2:8
3:16
However, the averaging can be bypassed and the
instantaneous filter output is compared against the threshold.
If the register
tx_dual_band_combiner_pap_mode_hpf_no_avg is set to 1
the averaging is disabled and instantaneous filter output is
compared against the threshold.
2.12.115 Register 51Ch (offset = 51Ch) [reset = 0h]
Figure 2-1318. Register 51Ch
7 6 5 4 3 2 1 0
TX_DUAL_BAN
D_COMBINER
_PAP_PWR_M
ETER_EN
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset

Table of Contents