www.ti.com
DAC JESD Register Map
351
SBAU337–May 2020
Submit Documentation Feedback
Copyright © 2020, Texas Instruments Incorporated
Serial Interface Register Maps
Table 2-457. Register 119 Field Descriptions
Bit Field Type Reset Description
7-0 ALARMS[15:8] R 0h
[8] = SRX1/5 LOS indicator
[9] = SRX2/6 LOS indicator
[10]= SRX3/7 LOS indicator
[11]= SRX4/8 LOS indicator
[12]= SRX1/5 Serdes-FIFO error
[13]= SRX2/6 Serdes-FIFO error
[14]= SRX3/7 Serdes-FIFO error
[15]= SRX4/8 Serdes-FIFO error
Note: Refer to the TI application note for details on error
interpretation.
Note: Refer to the TI application note for details on error
interpretation.
2.4.225 Register 11Ah (offset = 11Ah) [reset = 0h]
Figure 2-454. Register 11Ah
7 6 5 4 3 2 1 0
ALARMS[23:16]
R-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-458. Register 11A Field Descriptions
Bit Field Type Reset Description
7-0 ALARMS[23:16] R 0h
[23:16] = TIED to 0
Note: Refer to the TI application note for details on error
interpretation.
2.4.226 Register 11Bh (offset = 11Bh) [reset = 0h]
Figure 2-455. Register 11Bh
7 6 5 4 3 2 1 0
ALARMS[31:24]
R-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-459. Register 11B Field Descriptions
Bit Field Type Reset Description
7-0 ALARMS[31:24] R 0h
[27:24] = TIED to 0
[28]= JESDB: SRX1/5 Frame-Sync error (Ctrl-K in middle of
data)
JESDC: SRX1/5 Fixed ones error
[29]= JESDB: SRX2/6 Frame-Sync error (Ctrl-K in middle of
data)
JESDC: SRX2/6 Fixed ones error
[30]= JESDB: SRX3/7 Frame-Sync error (Ctrl-K in middle of
data)
JESDC: SRX3/7 Fixed ones error
[31]= JESDB: SRX4/8 Frame-Sync error (Ctrl-K in middle of
data)
JESDC: SRX4/8 Fixed ones error
Note: Refer to the TI application note for details on error
interpretation.