FB Top Register Map
www.ti.com
946
SBAU337May 2020
Submit Documentation Feedback
Copyright © 2020, Texas Instruments Incorporated
Serial Interface Register Maps
2.14.287 Register 5DCh (offset = 5DCh) [reset = 0h]
Figure 2-2170. Register 5DCh
7 6 5 4 3 2 1 0
FB_AGC_USE
_ALL_DETECT
ORS_AS_ATT
ACK
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-2184. Register 5DC Field Descriptions
Bit Field Type Reset Description
0-0
FB_AGC_USE_AL
L_DETECTORS_A
S_ATTACK
R/W 0h
Used only in external agc mode. When high, this will make all
the decay detectors also behave like attack detectors
2.14.288 Register 5E0h (offset = 5E0h) [reset = 0h]
Figure 2-2171. Register 5E0h
7 6 5 4 3 2 1 0
FB_AGC_RES
TART_MAX_MI
N
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-2185. Register 5E0 Field Descriptions
Bit Field Type Reset Description
0-0
FB_AGC_RESTAR
T_MAX_MIN
R/W 0h
Resetting statistics module. When Set to zero and set to one
reset all the statistics and start again. That is reset
rx_agc_max_attn_used, rx_agc_min_attn_used to
rx_agc_curr_attn. Reset rx_agc_max_dvga_attn_used
rx_agc_min_dvga_attn_used to rx_agc_cur_dvga_attn. Clear
all sticky bits. When high it continous updates the statistics
status based on loop operation. For statistics to be working
clk_en_agc_stat to be made high
2.14.289 Register 5E4h (offset = 5E4h) [reset = 0h]
Figure 2-2172. Register 5E4h
7 6 5 4 3 2 1 0
FB_AGC_MAX_ATTN_USED
R-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-2186. Register 5E4 Field Descriptions
Bit Field Type Reset Description
5-0
FB_AGC_MAX_AT
TN_USED
R 0h
Max attenuation seen by stat module. This is in 0.5 dB
resolution.