EasyManua.ls Logo

Texas Instruments AFE79 Series - 2.12.100 Register 502 h (offset = 502 h) [reset = 2 h]; 2.12.101 Register 503 h (offset = 503 h) [reset = 1 h]; 2.12.102 Register 504 h (offset = 504 h) [reset = 0 h]

Texas Instruments AFE79 Series
1268 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.ti.com
TX Top Register Map
663
SBAU337May 2020
Submit Documentation Feedback
Copyright © 2020, Texas Instruments Incorporated
Serial Interface Register Maps
2.12.100 Register 502h (offset = 502h) [reset = 2h]
Figure 2-1303. Register 502h
7 6 5 4 3 2 1 0
TX_PAP_RAMP_MULT_DATA_
MODE
R/W-2h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1315. Register 502 Field Descriptions
Bit Field Type Reset Description
1-0
TX_PAP_RAMP_M
ULT_DATA_MODE
R/W 2h
Register control to select the data which gets multiplied by the
ramp in the PA Protection mulitplication block. The 2 bit
implies the following:
0:Programmable Value is fed when the PA protection triggers.
The value can be programmed in register
tx_pap_ramp_mult_data.
1:Regular TX Data
2:On PA protection trigger, the last good sample is held. The
bad sample is not propagated in the TX chain.
3:Reserved:
2.12.101 Register 503h (offset = 503h) [reset = 1h]
Figure 2-1304. Register 503h
7 6 5 4 3 2 1 0
TX_PAP_RAM
P_MULT_EN
R/W-1h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1316. Register 503 Field Descriptions
Bit Field Type Reset Description
0-0
TX_PAP_RAMP_M
ULT_EN
R/W 1h
Enable PAP multiplication block.
0 : Disable
1 : Enable
2.12.102 Register 504h (offset = 504h) [reset = 0h]
Figure 2-1305. Register 504h
7 6 5 4 3 2 1 0
TX_PAP_RAMP_MULT_DATA[7:0]
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1317. Register 504 Field Descriptions
Bit Field Type Reset Description
7-0
TX_PAP_RAMP_M
ULT_DATA[7:0]
R/W 0h
Data input to PA protection ramp multiplier on selecting
tx_pap_ramp_mult_data_mode==0