EasyManua.ls Logo

Texas Instruments AFE79 Series - 2.12.165 Register 56 Ah (offset = 56 Ah) [reset = 0 h]; 2.12.166 Register 56 Ch (offset = 56 Ch) [reset = 0 h]

Texas Instruments AFE79 Series
1268 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.ti.com
TX Top Register Map
685
SBAU337May 2020
Submit Documentation Feedback
Copyright © 2020, Texas Instruments Incorporated
Serial Interface Register Maps
Table 2-1379. Register 569 Field Descriptions
Bit Field Type Reset Description
0-0
TX_IP_PAP_HPF_
MODE_NO_AVG
R/W 0h
The high pass filter output can be averaged ain a
programmable window of 2 to 16 samples. The averaged
output is compared against a threshold to determice the error
hit. However, the averaging can be bypassed and the
instantaneous filter output is compared against the threshold.
If this register bit is set ot 1 the averaging is disabled and
instantaneous filter output is comapred against the threshold
0 : Average enable
1 : Average disable
2.12.165 Register 56Ah (offset = 56Ah) [reset = 0h]
Figure 2-1368. Register 56Ah
7 6 5 4 3 2 1 0
TX_IP_PAP_HPF_SAMPLES
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1380. Register 56A Field Descriptions
Bit Field Type Reset Description
1-0
TX_IP_PAP_HPF_
SAMPLES
R/W 0h
The high pass filter output can be averaged in a
programmable window of 2 to 16 samples. The averaged
output is compared against a threshold to determine the error
hit.
0:2:
1:4:
2:8:
3:16:
However, the averaging can be bypassed and the
instantaneous filter output is compared against the threshold.
If the register tx_ip_pap_hpf_mode_no_avg is set to 1 the
averaging is disabled and instantaneous filter output is
compared against the threshold.
2.12.166 Register 56Ch (offset = 56Ch) [reset = 0h]
Figure 2-1369. Register 56Ch
7 6 5 4 3 2 1 0
TX_IP_PAP_P
WR_METER_E
N
R/W-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1381. Register 56C Field Descriptions
Bit Field Type Reset Description
0-0
TX_IP_PAP_PWR_
METER_EN
R/W 0h
For debug, a power meter at TX-JESD interface for each
band. The power meter measures the RMS power in a
window. The length of the window is programmed in the
register tx_ip_pap_moving_average_pwr_counter. This
regsiter controls the TX-JESD interface power meter enable.
0 : Disable
1 : Enable