RX Top Register Map
www.ti.com
838
SBAU337May 2020
Submit Documentation Feedback
Copyright © 2020, Texas Instruments Incorporated
Serial Interface Register Maps
2.13.430 Register 5D1h (offset = 5D1h) [reset = 0h]
Figure 2-1842. Register 5D1h
7 6 5 4 3 2 1 0
RX_AGC_AVG_PWR_DET_SEEN[15:8]
R-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1855. Register 5D1 Field Descriptions
Bit Field Type Reset Description
7-0
RX_AGC_AVG_P
WR_DET_SEEN[1
5:8]
R 0h
Indicates average power seen by the power detector. Based
on pwr_det_read_sel corresponding power detector is
selected. Update pulse needs to be provided for reading this.
Power read will be equal to 10 * log (value read/65535)
2.13.431 Register 5D4h (offset = 5D4h) [reset = 0h]
Figure 2-1843. Register 5D4h
7 6 5 4 3 2 1 0
RX_AGC_DIG_DET_NUM_HITS_SEEN[7:0]
R-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1856. Register 5D4 Field Descriptions
Bit Field Type Reset Description
7-0
RX_AGC_DIG_DE
T_NUM_HITS_SE
EN[7:0]
R 0h
Indicates Number of Hits observed. Based on
dig_det_read_sel the corresponding digital peak detector
status is read. This will get updated only when update pulse is
given.. Running accum mode should not be used when
interpreting this.
2.13.432 Register 5D5h (offset = 5D5h) [reset = 0h]
Figure 2-1844. Register 5D5h
7 6 5 4 3 2 1 0
RX_AGC_DIG_DET_NUM_HITS_SEEN[15:8]
R-0h
LEGEND: R/W = Read/Write; W = Write only; -n = value after reset
Table 2-1857. Register 5D5 Field Descriptions
Bit Field Type Reset Description
7-0
RX_AGC_DIG_DE
T_NUM_HITS_SE
EN[15:8]
R 0h
Indicates Number of Hits observed. Based on
dig_det_read_sel the corresponding digital peak detector
status is read. This will get updated only when update pulse is
given.. Running accum mode should not be used when
interpreting this.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments AFE79 Series and is the answer not in the manual?

Texas Instruments AFE79 Series Specifications

General IconGeneral
BrandTexas Instruments
ModelAFE79 Series
CategoryControl Unit
LanguageEnglish

Related product manuals