EasyManua.ls Logo

Texas Instruments AFE79 Series - Page 221

Texas Instruments AFE79 Series
1268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.ti.com
JESD_SUBCHIP Register Map
221
SBAU337May 2020
Submit Documentation Feedback
Copyright © 2020, Texas Instruments Incorporated
Serial Interface Register Maps
Table 2-157. Register C1 Field Descriptions (continued)
Bit Field Type Reset Description
6-6
APB_CLK_DIV_FA
CTOR_ODD
R/W 0h
Reduce the divide factor by 1. Applicable for all divide ratios of
6 and above (not applicable for divide ratio of 4)
If apb_clk_divide_factor = 2, and apb_clk_div_factor_odd=1,
the the divide ratio is 5
If apb_clk_divide_factor = 4, and apb_clk_div_factor_odd=1,
the the divide ratio is 7
If apb_clk_divide_factor = 8, and apb_clk_div_factor_odd=1,
the the divide ratio is 9
If apb_clk_divide_factor = 16, and apb_clk_div_factor_odd=1,
the the divide ratio is 11
If apb_clk_divide_factor = 32, and apb_clk_div_factor_odd=1,
the the divide ratio is 13
If apb_clk_divide_factor = 0, and apb_clk_div_factor_odd=1,
the the divide ratio is 15
When dithering is enabled (setting cfg_dithered_mode_en=1),
the divide factor will dynamically change between N and N-1
(one lower than the above mentioned divide factors).
If apb_clk_div_factor = 1, and apb_clk_div_factor_odd=1/0,
the the divide ratio is (3,4)
If apb_clk_div_factor = 2, and apb_clk_div_factor_odd=1, the
the divide ratio is (4,5)
If apb_clk_div_factor = 2, and apb_clk_div_factor_odd=0, the
the divide ratio is (5,6)
If apb_clk_div_factor = 4, and apb_clk_div_factor_odd=1, the
the divide ratio is (6,7)
If apb_clk_div_factor = 4, and apb_clk_div_factor_odd=0, the
the divide ratio is (7,8)
If apb_clk_div_factor = 8, and apb_clk_div_factor_odd=1, the
the divide ratio is (8,9)
If apb_clk_div_factor = 8, and apb_clk_div_factor_odd=0, the
the divide ratio is (9,10)
If apb_clk_div_factor = 16, and apb_clk_div_factor_odd=1, the
the divide ratio is (10,11)
If apb_clk_div_factor = 16, and apb_clk_div_factor_odd=0, the
the divide ratio is (11,12)
If apb_clk_div_factor = 32, and apb_clk_div_factor_odd=1, the
the divide ratio is (12,13)
If apb_clk_div_factor = 32, and apb_clk_div_factor_odd=0, the
the divide ratio is (13,14)
If apb_clk_div_factor = 0, and apb_clk_div_factor_odd=1, the
the divide ratio is (14,15)
If apb_clk_div_factor = 0, and apb_clk_div_factor_odd=0, the
the divide ratio is (15,16)
If apb_clk_divide_factor = 0, and apb_clk_div_factor_odd=1,
the the divide ratio is 15