EasyManua.ls Logo

Extreme Networks ExtremeWare - Configure Sonet Clocking Ports

Extreme Networks ExtremeWare
2254 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
configure sonet clocking ports
ExtremeWare Software 7.3.0 Command Reference Guide 1665
configure sonet clocking ports
configure sonet clocking [line | internal] ports <portlist>
Description
Configures the clocking source for the specified SONET ports.
Syntax Description
Default
The default setting is
internal
.
Usage Guidelines
The clock is recovered from the received bitstream when
line
clocking is configured.
Example
The following command example selects line clocking for port 1 of the PoS module installed in slot 8 of
the BlackDiamond switch:
config sonet clocking line ports 8:1
History
This command was first available in an ExtremeWare IP Technology Services Release based on
v6.1.5b20.
Platform Availability
This command is available on the BlackDiamond switch only.
line Sets the line clocking on the specified port.
internal Sets internal clocking on the specified port.
portlist Specifies the port number(s).

Table of Contents

Related product manuals