configure packet-mem-scan-recovery-mode
ExtremeWare Software 7.3.0 Command Reference Guide 641
configure packet-mem-scan-recovery-mode
configure packet-mem-scan-recovery-mode [offline | online] [msm-a | msm-b |
<slot number>]
Description
Configures packet memory scanning and the recovery mode setting on a BlackDiamond module.
Syntax Description
Default
Disabled.
Usage Guidelines
Use this command to scan and check the health of an individual module rather than the overall system.
This command overrides the system health check auto-recovery setting. If you have the system health
check alarm level configured, the individual packet memory scanning configuration is ignored.
This command is only effective if the system health check is configured for auto-recovery. If you have
the system health check configured for auto-recovery, and you configure packet-mem-scan-recovery, you
can define a specific slot’s behavior if an error is discovered.
To configure the system health check for auto-recovery, use the
configure sys-health-check
auto-recovery <number> [offline | online] | alarm-level [card-down | default | log |
system-down | traps]
command.
The alarm-level and auto-recovery options are mutually exclusive; configuring an alarm-level disables
auto-recovery, and configuring auto-recovery overrides the alarm-level setting.
offline Specifies that a faulty BlackDiamond module is taken offline and kept offline if
one of the following occurs:
More than eight defects are detected.
Three consecutive checksum errors were detected by the health checker,
but no new defects were found by the memory scanning and mapping
process.
After defects were detected and mapped out, the same checksum errors
are again detected by the system health checker.
online Specifies that a faulty module is kept online, regardless of how many errors
are detected.
msm-a Specifies the MSM module installed in slot A.
msm-b Specifies the MSM module installed in slot B.
slot number Specifies a module installed in a slot.