config inline-power usage-threshold
ExtremeWare Software 7.3.0 Command Reference Guide 1909
config inline-power usage-threshold
config inline-power usage-threshold <threshold>
Description
Sets the inline power usage alarm threshold.
Syntax Description
Default
70.
Usage Guidelines
This command
sets the threshold for initiation of an alarm if the measured power exceeds the
threshold. The alarm threshold is shared between the system-level utilization and the allocated
power budget per slot. If either measurement exceeds the threshold level, an alarm will be
initiated.
Example
The following command sets the
inline power usage alarm threshold
at 75%:
config inline-power usage-threshold 75
History
This command was first available in ExtremeWare 7.2.
Platform Availability
This command is available on Alpine series I/O modules only.
threshold Integer in the range 1 – 99 expressed as a percentage for derating of available
power to measured power. The default value is 70.