1908 ExtremeWare Software 7.3.0 Command Reference Guide
Power Over Ethernet Commands
config inline-power type
config inline-power type [phone | webcam | wireless | other] ports
<portlist>
Description
Sets the type of power device (PD) connected to the specified ports.
Syntax Description
Default
N/A.
Usage Guidelines
This command sets the type of PD connected to the specified ports. This is a management-controlled
entity because there is no support for dynamically determining the PD device type.
Use the
detail port
argument in the show inline-power info [port <portlist | detail port <portlist]
command to display the inline-power type for a selected port.
Example
The following command specifies the type of PD connected to port 3 on slot 4 as a wireless device:
config inline-power type wireless ports 4:3
History
This command was first available in ExtremeWare 7.2.
Platform Availability
This command is available on Alpine series I/O modules only.
phone Specifies the PD connected to the specified port as a phone.
webcam Specifies the PD connected to the specified port as a webcam.
wireless Specifies the PD connected to the specified port as a wireless device.
other Specifies the PD connected to the specified port as a power device other than
a phone, a webcam, or a wireless device.
portlist Specifies one or more slots and ports. May be in the form 2:*, 2:5, 2:6-2:8.