EasyManua.ls Logo

Extreme Networks ExtremeWare - Config Inline-Power Violation-Precedence

Extreme Networks ExtremeWare
2254 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1910 ExtremeWare Software 7.3.0 Command Reference Guide
Power Over Ethernet Commands
config inline-power violation-precedence
config inline-power violation-precedence [advertised-class | operator-limit
| max-class-operator | none] ports <portlist>
Description
Sets the violation precedence for the specified ports
.
Syntax Description
Default
max-class-operator
Usage Guidelines
This command sets the violation precedence for the specified ports. Power will be removed or denied to
PDs connected to the selected ports if the PD consumes more power than the entered limit. The default
value is
max-class-operator
, which removes or denies power if the PD consumes power beyond the
greater value of the detected class limit or the configured operator limit, whichever is greater. The
operator limit is configured with the following command:
config inline-power operator-limit <milliwatts> ports <portlist>
Example
The following command sets the violation precedence for port 3 on slot 5 to the configured operator
limit:
config inline-power violation-precedence operator-limit ports 5:3
History
This command was first available in ExtremeWare 7.2.
Platform Availability
This command is available on Alpine series I/O modules only.
advertised-class Removes or denies power if an IEEE 802.3af-compliant power device (PD)
consumes power beyond its advertised class limit.
operator-limit Removes or denies power if the PD consumes power beyond the configured
operator limit.
max-class-operator Removes or denies power if the PD consumes power beyond the detected
class limit or the operator limit, whichever is greater. Max-class-operator is the
default value.
none Removes or denies power if the PD exceeds the maximum limit of 20 watts.
portlist Specifies one or more slots and ports. May be in the form 2:*, 2:5, 2:6-2:8.

Table of Contents

Related product manuals