configure flow-redirect timer service-check
ExtremeWare Software 7.3.0 Command Reference Guide 451
configure flow-redirect timer service-check
configure flow-redirect timer service-check frequency <seconds> timeout
<seconds>
Description
Configures the flow redirect service-check frequency and timeout.
Syntax Description
Default
The default frequency is 60 seconds.
The default timeout is 180 seconds.
Usage Guidelines
The frequency must be less than the timeout.
This frequency and timeout apply to all layer 7 service checks.
Example
The following command configures a flow redirect service-check frequency of 100 seconds and a
timeout of 300 seconds:
configure flow-redirect timer service-check frequency 100 timeout 300
History
This command was first available in ExtremeWare 6.2.1.
Platform Availability
This command is available on all platforms.
frequency Specifies the service-check frequency. The range is 15 to 300.
timeout Specifies the service-check timeout. The range is 15 to 300.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extreme Networks ExtremeWare and is the answer not in the manual?

Extreme Networks ExtremeWare Specifications

General IconGeneral
BrandExtreme Networks
ModelExtremeWare
CategorySoftware
LanguageEnglish

Related product manuals