configure sys-health-check auto-recovery
ExtremeWare Software 7.3.0 Command Reference Guide 651
configure sys-health-check auto-recovery
configure sys-health-check auto-recovery <number> [offline | online] |
alarm-level [card-down | default | log | system-down | traps]
Description
Configures the system health checker.
Syntax Description
Default
Log.
Usage Guidelines
This command allows you to configure the switch’s reaction to a failed health check.
The system health checker tests I/O modules, MSM modules, and the backplane by forwarding packets
every 4 seconds. Additional checking for the validity of these packets is completed by performing a
checksum.
By isolating faults to a specific module, MSM, or backplane connection, the system health checker
prevents corrupted packets from being propagated to the CPU, upper layer modules, or the rest of your
network. If you observe a failure, please contact Extreme Technical Support.
Depending on how you have configured the system health checker, failed system health checks may
generate critical error messages in the syslog, and may also send a trap and/or shut down the system.
The system health checker will continue to periodically forward test packets to failed components. If
auto-recovery is configured, the system will attempt to automatically reset the faulty module and bring
it back online.
number Specifies the number of times that the health checker attempts to auto-recover
a faulty module. The range is from 0 through 255 times. Default is 3 times.
Applies only to BlackDiamond I/O modules.
offline Specifies that a faulty module is taken offline and kept offline if one of the
following occurs:
• More than eight defects are detected.
• Three consecutive checksum errors were detected by the health checker,
but no new defects were found by the memory scanning and mapping
process.
• After defects were detected and mapped out, the same checksum errors
are again detected by the system health checker.
online Specifies that a faulty module is kept online, regardless of memory scanning
or memory mapping errors.
card-down Posts a CRIT message to the log and brings the module down.
default Resets the alarm level to log.
log Posts a CRIT message to the log.
system-down Posts a CRIT message to the log, sends a trap, and turns off the system.
traps Posts a CRIT message to the log and sends a trap.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extreme Networks ExtremeWare and is the answer not in the manual?

Extreme Networks ExtremeWare Specifications

General IconGeneral
BrandExtreme Networks
ModelExtremeWare
CategorySoftware
LanguageEnglish

Related product manuals