1934 ExtremeWare Software 7.3.0 Command Reference Guide
Power Over Ethernet Commands
unconfig inline-power operator-limit ports
unconfig inline-power operator-limit ports <portlist>
Description
Resets the operator limit back to the default for the specified ports.
Syntax Description
Default
The default operator limit is 15400 mW.
Usage Guidelines
This command resets the operator limit configured with the following command:
config inline-power operator-limit <milliwatts> ports <portlist>
Example
The following command resets the operator limit to its default for port 2 on slot 1:
unconfig inline-power operator-limit ports 1:2
History
This command was first available in ExtremeWare 7.2.
Platform Availability
This command is available on Alpine series I/O modules only.
portlist Specifies one or more slots and ports. May be in the form 2:*, 2:5, 2:6-2:8.