configure transceiver-test window
ExtremeWare Software 7.3.0 Command Reference Guide 665
configure transceiver-test window
configure transceiver-test window <1-8>
Description
Configures the number of 20-second windows within which the configured number of errors can occur.
Syntax Description
Default
8 windows.
Usage Guidelines
Use this feature when the switch can be brought off-line.
This configuration provides a sliding window. If you keep the window configuration at 8, the switch
checks for errors within the last eight 20-second windows.
To determine the number of errors the switch accepts before it takes action, use the
configure
transceiver-test threshold
command.
Extreme Networks does not recommend changing the default transceiver test window parameter. The
default parameter is adequate for most networks.
Example
The following command configures the switch to check for errors within the last seven 20-second
windows:
configure transceiver-test window 7
History
This command was first available in ExtremeWare 6.2.2b108.
This command was not supported in ExtremeWare 7.0.
This command is supported in ExtremeWare 7.1.0.
Platform Availability
This command is available on modular switches only.
window Specifies the number of 20-second windows. The range is 1 to 8 20-second
windows.