EasyManua.ls Logo

Extreme Networks ExtremeWare - Configure Ports E1 Framing

Extreme Networks ExtremeWare
2254 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
configure ports e1 framing
ExtremeWare Software 7.3.0 Command Reference Guide 1699
configure ports e1 framing
configure ports <portlist> e1 framing [crc4 | no-crc4]
Description
Configure framing for E1 links.
Syntax Description
Default
CRC4 framing is enabled by default.
Usage Guidelines
Framing is used to synchronize data transmission on the line. Framing allows the hardware to
determine when each packet starts and ends. The two choices for E1 framing are CRC4 and No-CRC4.
Example
The following command sets framing to CRC4 for the E1 ports:
configure ports 3:1-3:4 e1 framing crc4
History
This command was first available in ExtremeWare v6.1.8w3.0.1b56 WAN technology release.
This command was subsequently incorporated into ExtremeWare 7.0.0.
Platform Availability
This command is available on the Alpine 3800 series platform, when a WAN module is installed.
portlist A list of ports.
crc4 Specifies CRC4 framing.
no-crc4 Specifies No-CRC4 framing.

Table of Contents