config inline-power display-string
ExtremeWare Software 7.3.0 Command Reference Guide 1905
config inline-power display-string
config inline-power display-string <string> ports <portlist>
Description
Lets you create your own label for a specified power port.
Syntax Description
Default
No label.
Usage Guidelines
Use the
show inline-power configuration port
command, as shown in the following example, to
display inline power configuration information, including the display string (if any) for each port. The
display string is shown under the “Label” column:
show inline-power configuration port 1:1-1:7
Following is sample output from this command:
Port Config Detect Rsvd Pwr Oper Lmt Viol Prec Label
1:1 enabled auto 0.0 15.4 max-class-operator
1:2 enabled auto 10.0 15.4 advertised-limit test_port2
1:3 enabled auto 0.0 15.4 max-class-operator
1:4 enabled auto 0.0 15.4 max-class-operator
1:5 enabled auto 0.0 15.4 max-class-operator
1:6 enabled auto 0.0 15.4 max-class-operator test_port6
1:7 enabled auto 0.0 15.4 max-class-operator
Example
The following command assigns the name “alpha-test_1” to port 1 on slot 4:
config inline-power display-string alpha-test_1 ports 4:1
History
This command was first available in ExtremeWare 7.2.
Platform Availability
This command is available on Alpine series I/O modules only.
string Specifies a name up to 13 characters in length to identify the specified power
port(s).
portlist Specifies one or more slots and ports. May be in the form 2:*, 2:5, 2:6-2:8.