configure sflow collector
ExtremeWare Software 7.3.0 Command Reference Guide 645
configure sflow collector
configure sflow collector <ip-address> : <udp-port>
Description
Configures the IP address and UDP port number identifying the sFlow collector.
Syntax Description
Default
UDP port number—6343
Usage Guidelines
This command allows you to configure where to send the sFlow data. You must specify an IP address
for the sFlow data collector, and a UDP port where the samples will be transmitted to and from the
sFlow agent.
You can configure up to four sFlow collectors. Each unique IP address/UDP port combination identifies
a collector.
Using the
unconfigure sflow collector
command will reset the collector parameters to the default.
Example
The following command specifies that the sFlow agent will send all samples to the collector with the
address 123.123.123.123 and port 9876:
configure sflow collector 123.123.123.123 : 9876
History
This command was first available in ExtremeWare 7.3.0.
Platform Availability
This command is available on all platforms.
ip-address Specifies the IP address to send the sFlow data.
udp-port Specifies the UDP port number to send the sFlow data.