1926 ExtremeWare Software 7.3.0 Command Reference Guide
Power Over Ethernet Commands
Curr—Displays the measure current in milli Amps (mA).
Res—Displays the measured resistance in kilo Ohms (Kohms). A value greater than 100 Kohms
indicates an empty port.
Power—Displays the measured power in watts.
Fault—Displays the fault value:
0: No fault
1: Over voltage
2: Over voltage spike
3: Peak over current
4: Overload
8: Discovery resistance failed
9: Class violation
10: Disconnect
11: Discovery resistance, A2D fail
12: Classify, A2D fail
13: Sample A2D fail
14: Device fault, A2D fail
The detail command lists all inline power information for the selected ports. Detail output displays the
following information:
Configured Admin State
Inline Power State
MIB Detect Status
Label
Violation Precedence
Operator Limit
Detection
Reserved Power
Inline Type
Connect Order
PD Class
Max Allowed Power
Measured Power
Line Voltage
Discovered Resistance
Discovered Capacitance
Current
Fault Status