show slot
ExtremeWare Software 7.3.0 Command Reference Guide 305
As the module progresses through its initialization, the
show slot <slot>
command displays the
general purpose processor (GPP) subsystem change state to OPERATIONAL, and then each of the
network processors will change state to OPERATIONAL.
When the GPP subsystem completes its initialization cycle and the subsystem state is
OPERATIONAL, use the
show diagnostics {<slot>}
command to check the results of the
module power-on self test (POST).
If the STATUS LED on the ARM, ATM, MPLS or PoS module turns amber and blinks, use the
show
slot <slot>
command to display the slot status information. The
show slot <slot>
command also
displays operational information related to the ARM, ATM, MPLS or PoS module. Information
displayed includes the BlackDiamond switch fabric card state, Network Processor status, General
Purpose Processor status, hardware serial number and type, and image version and boot settings.
For the ARM, ATM, MPLS, PoS, and WAN modules, the information displayed by this command
includes data about the software images loaded on the module and information about the operational
status and backplane connections of the module.
Example
The following example displays module information for all slots:
show slot
Following is the output from this command:
Slot 1 information:
State: Operational
Serial number: 701028-06-0026F38445
HW Module Type: G8Ti
Configured Type: Not configured
UTP ports available:
Link Active:
Link Down: 01 02 03 04 05 06 07 08
Slot 2 information:
State: Operational
Serial number: 701024-19-0125F06190
HW Module Type: G8Xi
Configured Type: Not configured
Gigabit ports available:
Link Active:
Link Down: 01
GBIC missing: 02 03 04 05 06 07 08
Slot 3 information:
State: Operational
Serial number: 701020-11-0032F51006
HW Module Type: G12SXi
Configured Type: Not configured
Gigabit ports available: