C613-50631-01 Rev A Command Reference for IE340 Series 1348
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
BGP AND BGP4+ COMMANDS
BGP
NEXTHOP-TRIGGER DELAY
bgp nexthop-trigger delay
Overview Use this command to set the delay interval for next hop address tracking.
Use the no variant of this command to reset the timer value to the default.
Syntax
bgp nexthop-trigger delay <1-100>
no bgp nexthop-trigger delay
Default The default next hop delay interval is 5 seconds.
Mode Global Configuration
Usage This command configures the delay interval between routing table waits for next
hop delay tracking. The delay interval determines how long BGP waits after it
receives the trigger from the system about one or more next hop changes before
it walks the full BGP table to determine which prefixes are affected by the next hop
changes.
Example To set the next hop delay interval to 6 seconds, enter the command:
awplus# configure terminal
awplus(config)# bgp nexthop-trigger delay 6
Related
commands
bgp nexthop-trigger-count
bgp nexthop-trigger enable
Command
changes
Added to AlliedWare Plus prior to 5.4.6-1
Version 5.4.7-2.1: BGP support added for x510 and x550 series
Version 5.4.7-2.4: BGP support added for IE300 series
Parameter Description
<1-100> Next hop trigger delay interval in seconds.

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals