C613-50631-01 Rev A Command Reference for IE340 Series 2715
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
G.8032 ETHERNET RING PROTECTION SWITCHING COMMANDS
G
8032 MANUAL-SWITCH ERP-INSTANCE
g8032 manual-switch erp-instance
Overview Use this command to manually cause a protection switch on a G.8032 Ethernet
Ring Protection (ERP) instance ring port.
Syntax
g8032 manual-switch erp-instance <erp-instance-name>
{east-interface|west-interface|terminating-interface}
Mode Privileged Exec
Usage notes G.8032 supports a Manual Protection Switch action initiated by the operator. A
Manual Protection Switch command is to be issued at a given G.8032 node and
given port in the ring. This results in a block being applied at that ring port (and an
unblock on the opposite ring port), and a R-APS designated Manual Switch
message to flow around the ring causing the RPL to become unblocked.
The difference between a Manual switch and a Forced switch is that the Manual
Switch will be ignored under various conditions. In particular, only one Manual
Switch is allowed on a G.8032 ring at a time.
If the G.8032 Physical Ring instance associated with the specified ERP instance is
set to terminating-interface, then only one ring port is available and
terminating-interface must be used in this command, otherwise specify the
east-interface or the west-interface.
To clear this action command, use the clear g8032 erp-instance command.
Example To issue a Manual Protection Switch on the East interface of an ERP instance named
“blue”, use the following command:
awplus# g8032 manual-switch erp-instance blue east-interface
Related
commands
clear g8032 erp-instance
g8032 erp-instance
Command
changes
Version 5.4.7-0.1: command added
Version 5.4.7-1.1: added to x310 series products
Version 5.4.7-2.1: added to x550 series products
Version 5.4.8-0.2: added to SBx8100 series products
Version 5.4.8-1.1: added to SBx908 GEN2 series products
Parameter Description
<erp-instance-name> The name of the G.8032 ERP instance
east-interface The G.8032 ERP instance's East ring port
west-interface The G.8032 ERP instance's West ring port
terminating-interface The G.8032 ERP instance's Terminating ring port

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals