C613-50631-01 Rev A Command Reference for IE340 Series 3236
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
LLDP COMMANDS
LLDP
TX-DELAY
lldp tx-delay
Overview This command sets the value of the transmission delay timer. This is the minimum
time interval between transmitting LLDP advertisements due to a change in LLDP
local information.
The no variant of this command sets the transmission delay timer back to its
default setting.
Syntax
lldp tx-delay <1-8192>
no lldp tx-delay
Default The default transmission delay timer is 2 seconds.
Mode Global Configuration
Examples To set the transmission delay timer to 12 seconds, use the commands:
awplus# configure terminal
awplus(config)# lldp tx-delay 12
To set the transmission delay timer back to its default, use the commands:
awplus# configure terminal
awplus(config)# no lldp tx-delay
Related
commands
lldp timer
show lldp
Parameter Description
<1-8192> The transmission delay in seconds. The transmission delay cannot be
greater than a quarter of the transmit interval (lldp timer command).

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals