C613-50631-01 Rev A Command Reference for IE340 Series 3236
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
LLDP COMMANDS
LLDP
TX-DELAY
lldp tx-delay
Overview This command sets the value of the transmission delay timer. This is the minimum
time interval between transmitting LLDP advertisements due to a change in LLDP
local information.
The no variant of this command sets the transmission delay timer back to its
default setting.
Syntax
lldp tx-delay <1-8192>
no lldp tx-delay
Default The default transmission delay timer is 2 seconds.
Mode Global Configuration
Examples To set the transmission delay timer to 12 seconds, use the commands:
awplus# configure terminal
awplus(config)# lldp tx-delay 12
To set the transmission delay timer back to its default, use the commands:
awplus# configure terminal
awplus(config)# no lldp tx-delay
Related
commands
lldp timer
show lldp
Parameter Description
<1-8192> The transmission delay in seconds. The transmission delay cannot be
greater than a quarter of the transmit interval (lldp timer command).