C613-50631-01 Rev A Command Reference for IE340 Series 533
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
ALARM MONITORING COMMANDS
ALARM
FACILITY G8032 RELAY
alarm facility g8032 relay
Overview Use this command to trigger an alarm relay if one or more G.8032 ERP instances are
in the PROTECTION state.
This will activate the device that you have connected to the switch’s relay output
(for example, you could connect a buzzer to the relay output).
Use the no variant of this command to remove this alarm.
Syntax
alarm facility g8032 relay
no alarm facility g8032 relay
Default By default, there are no alarms
Mode Global Configuration
Usage notes You can also use an alarm to flash the fault LED, by using the command alarm
facility g8032 led.
Example To trigger the alarm relay if one or more G.8032 ERP instances are in the
PROTECTION state, use the commands:
awplus# configure terminal
awplus(config)# alarm facility g8032 relay
To remove that alarm, use the commands:
awplus# configure terminal
awplus(config)# no alarm facility g8032 relay
Related
commands
alarm facility g8032 led
show alarm facility settings
show alarm facility status
Command
changes
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches