EasyManuals Logo

Allied Telesis IE340 Series User Manual

Allied Telesis IE340 Series
3474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #781 background imageLoading...
Page #781 background image
C613-50631-01 Rev A Command Reference for IE340 Series 781
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
UNIDIRECTIONAL LINK DETECTION (UDLD) COMMANDS
UDLD
TIME DISABLE-PERIOD
udld time disable-period
Overview Use this command to set the UDLD disable period on all interfaces. The disable
period is the time (in seconds) that a port is marked disabled before UDLD
attempts to recheck it.
Manually reset the UDLD status of a port using the udld reset command.
Use the no variant of this command to reset the disable period to infinite.
Syntax
udld time disable-period <seconds>
no udld time disable-period
Default The default time disable period is infinite.
Mode Global Configuration
Example To change the UDLD disable period to 60 sec on all interfaces, use the commands:
awplus# configure terminal
awplus(config)# udld time disable-period 60
To reset the disable period to infinite, use the commands:
awplus# configure terminal
awplus(config)# no udld time disable-period
Related
commands
udld enable
udld port
show udld
Parameter Description
<seconds> 30-86400 
Specify the disable period in seconds.

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals