EasyManuals Logo

Allied Telesis IE340 Series User Manual

Allied Telesis IE340 Series
3474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3403 background imageLoading...
Page #3403 background image
68
C613-50631-01 Rev A Command Reference for IE340 Series 3403
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Ping-Polling
Commands
Introduction
Overview This chapter provides an alphabetical reference for commands used to configure
Ping Polling. For more information, see the Ping Polling Feature Overview and
Configuration Guide.
For information on filtering and saving command output, see the “Getting Started
with AlliedWare Plus” Feature Overview and Configuration Guide.
Command List •“active (ping-polling)” on page 3405
•“clear ping-poll” on page 3406
•“critical-interval” on page 3407
•“debug ping-poll” on page 3408
Table 68-1: The following table lists the default values when configuring a ping
poll
Default Value
Critical-interval 1 second
Description No description
Fail-count 5
Length 32 bytes
Normal-interval 30 seconds
Sample-size 5
Source-ip The IP address of the interface from which the ping packets are
transmitted
Time-out 1 second
Up-count 30

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals